Introduction to fNIRS Beyond the Modified Beer-Lambert Law
Introduction to fNIRS
0% Completed

Beyond the Modified Beer-Lambert Law: Models, Sensitivity, and Depth

Over the last four lessons, we built the standard fNIRS calculation piece by piece. Light in tissue is absorbed and scattered (Lesson 2.1), the MBLL converts changes in attenuation into changes in concentration (Lesson 2.2), two wavelengths separate HbO₂ from HbR (Lesson 2.3), and many channels together can produce maps and images (Lesson 2.4). Along the way, we kept running into the same limits: an assumed DPF, a signal diluted by partial volume, and a scalp that contributes more than we would like.

This lesson steps back and looks at the MBLL from the outside. We will place it in the family of light transport models it belongs to, show that it is a special case of the same sensitivity equation used for tomography, and use that view to explain where depth sensitivity comes from and how different instruments try to improve it. We will close Unit 2 with a consolidated picture of what CW fNIRS can and cannot measure. None of this requires you to solve an equation yourself; the goal is to know what sits underneath the numbers your software gives you.

1. A Family of Models for Light in Tissue

Every fNIRS analysis uses a model of how light travels through tissue, even when that model is hidden inside a toolbox. The models differ in how much of the physics they keep, and therefore in what they can tell you. The table below lists the four you will meet most often in the literature, from the most complete to the simplest.

Model What it describes Typical use in fNIRS
Radiative transfer equation (RTE) The balance of light energy traveling in every direction at every point, including each absorption and scattering event. The most complete description at the scale that matters for fNIRS. Rarely solved directly; it is the reference against which the simpler models are checked.
Monte Carlo simulation Follows millions of simulated photons through a tissue model, drawing each scattering and absorption event at random. With enough photons, it converges to the solution of the RTE. The reference method for realistic, layered heads. Used to compute DPF, PPF, and sensitivity maps (e.g., with MCX; Fang & Boas, 2009).
Diffusion equation An approximation of the RTE in which light spreads like a diffusing substance. Valid when scattering dominates (\(\mu_s’ \gg \mu_a\)) and at distances of more than a few millimeters from sources and boundaries. Analytical solutions for simple geometries (semi-infinite, slab, layered media) and numerical solutions for anatomical heads (e.g., finite elements in NIRFAST; Dehghani et al., 2008). The usual forward model for DOT.
Linear perturbation Assumes that absorption changes are small, so that the change in the measurement is proportional to the change in \(\mu_a\). Every functional analysis: the MBLL for single channels, and the sensitivity (Jacobian) equation for DOT.

These models are not competitors. They form a hierarchy: each is an approximation of the one above it, valid under stated conditions. A well-known example of where the conditions fail is the layer of cerebrospinal fluid (CSF) around the brain, which scatters much less than the surrounding tissue. Diffusion is less accurate there, which is one reason Monte Carlo simulations are preferred for realistic head models.

The MBLL sits at the bottom of this hierarchy. That makes it the fastest and simplest model, and also the one that carries the most assumptions. The next section shows exactly which simplification turns the more complete picture into the MBLL.

2. What the MBLL Really Is: One Voxel of a Sensitivity Map

In Lesson 2.4, we saw that diffuse optical tomography relies on a sensitivity matrix: for each location in the head, how much a small absorption change at that location would change each measurement. The same idea is the key to understanding the MBLL.

Imagine dividing the tissue under a channel into small volumes (voxels). For small changes, the change in optical density is the sum of the absorption changes in all voxels, each weighted by how sensitive the measurement is to that voxel:

💡 The Sensitivity Equation

$$\Delta OD = \sum_{v} J_v \, \Delta\mu_{a,v}$$

where:

  • ΔOD is the change in optical density at one wavelength (natural-log convention, as discussed in Lesson 2.2).
  • Δμa,v is the change in the absorption coefficient within voxel v.
  • Jv is the sensitivity of the measurement to voxel v. For CW intensity measurements, it has a simple physical meaning: it is the mean partial path length of the detected light within that voxel. Plotted across the head, the values of Jv form the banana-shaped sensitivity profile from Lesson 2.1.

Now make the central assumption of the MBLL: the absorption change is the same everywhere in the sampled volume, so that Δμa,v = Δμa for every voxel. The absorption change then comes out of the sum:

$$\Delta OD = \Delta\mu_a \sum_{v} J_v = \Delta\mu_a \, \langle L \rangle = \Delta\mu_a \, d \cdot DPF$$

The sum of the partial path lengths over all voxels is simply the mean total path length ⟨L⟩, which is exactly what d · DPF represents. Writing \(\Delta\mu_a = \sum_i \epsilon_i \Delta c_i\) gives back the MBLL from Lesson 2.2.

In other words, the MBLL is the sensitivity equation with a single voxel. DOT keeps the full map; the MBLL collapses it into one number per channel. Seen this way, three concepts from Lesson 2.2 turn out to be three ways of summing the same map:

  • DPF: the sum over all voxels, divided by the source-detector separation d.
  • PPF: the sum over the voxels of one layer (for example, the cortex), divided by d.
  • Partial volume effect: the activation fills only some of the cortical voxels, so only their share of the sensitivity contributes to the signal.

📝 A Worked Example (Illustrative Numbers)

Consider a channel with a 3 cm separation and a DPF of 6, so the mean path length is 18 cm. Suppose that, on average, 1.5 cm of that path lies within the cortex beneath the probe and 6 cm lies within the scalp. (These values are illustrative; the real ones depend on the head, the wavelength, and the probe position.)

If only the cortex changes, by Δμa, the measured ΔOD is 1.5 cm × Δμa. The MBLL divides this by 18 cm and reports a change of Δμa/12: twelve times smaller than the true cortical change.

If instead only the scalp changes, by the same Δμa, the measured ΔOD is 6 cm × Δμa: four times larger than the cortical signal. This is why fNIRS concentration changes are best read as relative, why their absolute magnitudes are hard to compare across people and studies, and why the scalp has such a large influence on the signal.

💭 Pause and Think

Two participants perform the same task and have exactly the same cortical response. Participant A has a thicker scalp and skull than participant B. You analyze both with the same DPF. Whose ΔHbO₂ will look larger, and why?

Think about what happens to the partial path length in the cortex when the layers above it are thicker. What would you need to know to compare the two participants fairly?

3. Where Depth Sensitivity Comes From

The sensitivity map also explains the limits on depth. Detected light always has to enter and leave through the scalp, so every channel is most sensitive to the superficial layers close to the source and the detector, and its sensitivity falls off with depth.

Monte Carlo simulations in a realistic adult head model put numbers on this (Strangman et al., 2013). Sensitivity decreased roughly exponentially with depth, so fNIRS signals in adults are strongly weighted toward the outermost 10–15 mm of the intracranial space. Increasing the source-detector separation from 20 mm to about 45 mm increased the sensitivity to gray matter by about 4% for every additional 10 mm.

Longer separations reach deeper, but at a price: fewer photons survive the longer paths, so the signal becomes weaker and noisier. This trade-off is what sets the familiar 3–4 cm separation in adults, and the shorter separations used in infants, whose thinner scalp and skull let light reach the brain over shorter distances.

🔬 Explore It Yourself

Change the source-detector separation and watch the share of sensitivity below the cortex. Compare the short channel with the adult standard, and try the infant-like preset, where the cortex is closer to the surface. Keep in mind that this is a homogeneous model: in a real head, the share reaching the brain is smaller.

📖 SHOULD-READ PAPER

Strangman, G.E., Li, Z. & Zhang, Q. (2013). “Depth sensitivity and source-detector separations for near infrared spectroscopy based on the Colin27 brain template.” PLoS ONE, 8(8), e66319.

Using 3,555 Monte Carlo simulations covering the scalp of a standard adult head template, the authors mapped how the sensitivity of fNIRS to the brain depends on source-detector separation, depth, and position on the head. It is one of the clearest quantitative answers to the question “how much of my signal comes from the brain?”, and it is openly available.

→ doi:10.1371/journal.pone.0066319

Because the scalp always dominates, the useful question is not how to make a channel insensitive to it, but how to tell the superficial and deep contributions apart. There are three main strategies, and all of them build on the sensitivity idea from Section 2:

  • Combine different separations. A short channel is sensitive almost only to the scalp, while a long channel is sensitive to both scalp and brain. Comparing the two separates their contributions (Lesson 2.4; Unit 5 shows how this is done in analysis).
  • Use when photons arrive, not just how many. In time-domain systems, photons that arrive late have, on average, traveled longer and deeper paths, so they are more sensitive to the brain than early photons. This gives depth selectivity even from a single source-detector pair (Liebert et al., 2004). In frequency-domain systems, the phase of the detected light plays a similar role.
  • Reconstruct an image. With many overlapping measurements, DOT solves for the whole sensitivity map instead of collapsing it into one number (Lesson 2.4).

Unit 4 explains the instruments behind these strategies and what each costs in complexity.

4. What CW fNIRS Can and Cannot Measure

We can now put the pieces of Units 1 and 2 together in one place. The table below summarizes what the main classes of NIRS measurement give you. It refers to typical systems; specific devices and analysis methods can shift some of the entries.

Quantity Single-distance CW Multi-distance CW FD / TD
Changes in HbO₂ and HbR Yes, scaled by an assumed DPF and diluted by partial volume Yes, with the option to regress out the scalp Yes, with a measured rather than assumed path length
Absolute μa and μs′ No Not separately without assumptions about scattering Yes, within the assumptions of the model used
Absolute concentrations and StO₂ No StO₂ can be estimated from how intensity changes with distance, the approach used by many clinical oximeters Yes
Depth discrimination No Partial (short vs. long channels) Partial (late photons, phase), better when combined with multiple distances
Blood flow No No No; requires DCS or related techniques (Unit 4)
Oxygen metabolism (CMRO₂) No No Not on its own; flow is also needed (Lesson 1.3)

Two messages stand out. First, every quantity that standard CW fNIRS reports is a relative change, filtered through a model whose assumptions you now know. Second, most of what CW fNIRS cannot do is not a limitation of optics itself. It is the price of measuring only intensity at one distance. Adding distances, arrival times, phase, or speckle fluctuations recovers more of the physics, at a cost in complexity.

💭 Pause and Think

A clinical colleague shows you a cerebral oximeter reading StO₂ = 65% and asks whether your research CW fNIRS system could give the same number. What would you tell them?

What does the oximeter measure that a standard single-distance fNIRS channel does not? Which assumptions does it rely on to turn that measurement into a saturation value?

5. Where to Go Deeper

This course deliberately stops here. Solving the diffusion equation, building a Monte Carlo model of a head, and reconstructing a DOT image are the subject of a future SfNIRS course on the theory of diffuse optics, which builds directly on this unit. If you want to read ahead, the references at the end of this lesson are good starting points. The review by Durduran and colleagues (2010) is a natural next step: it develops the diffusion model for NIRS, DOT, and diffuse correlation spectroscopy in one place.

🎉 Unit 2 Complete

You now know how fNIRS turns light into numbers: how light interacts with tissue, how the MBLL and two wavelengths give ΔHbO₂ and ΔHbR, how channels become maps and images, and which model sits underneath each step. Just as important, you know which assumptions each step makes, and where they break down.

Unit 3 turns from physics to physiology. Now that you know what the numbers are, we will ask what they mean: why does neural activity change HbO₂ and HbR at all, and why in the directions we observe?


📌 Key Takeaways

  • Models of light in tissue form a hierarchy: the radiative transfer equation, Monte Carlo simulation (which converges to it), the diffusion equation (valid when scattering dominates and away from sources and boundaries), and linear perturbation. The MBLL sits at the bottom: simplest, fastest, and with the most assumptions.
  • For small changes, ΔOD = Σ Jv Δμa,v, where Jv is the mean partial path length in voxel v. The MBLL is this equation with a single, uniform change: Σ Jv = ⟨L⟩ = d · DPF.
  • DPF, PPF, and the partial volume effect are three ways of summing the same sensitivity map. This is why the MBLL underestimates focal cortical changes and why scalp changes weigh so heavily in the signal.
  • Sensitivity is highest in superficial tissue and falls roughly exponentially with depth. Depth discrimination comes from combining separations, from photon arrival times or phase (TD/FD), or from tomographic reconstruction.
  • Standard CW fNIRS reports relative changes only. Absolute concentrations, StO₂, depth discrimination, blood flow, and oxygen metabolism all require more information than intensity at a single distance.

📚 Further Reading & Key References

  1. Strangman, G.E., Li, Z. & Zhang, Q. (2013). “Depth sensitivity and source-detector separations for near infrared spectroscopy based on the Colin27 brain template.” PLoS ONE, 8(8), e66319. [doi] — Quantitative map of fNIRS sensitivity to the brain as a function of separation and depth in a realistic adult head.
  2. Durduran, T., Choe, R., Baker, W.B. & Yodh, A.G. (2010). “Diffuse optics for tissue monitoring and tomography.” Reports on Progress in Physics, 73(7), 076701. [doi] — A thorough review of the diffusion model and its use in NIRS, DOT, and diffuse correlation spectroscopy. The natural next step after this unit.
  3. Arridge, S.R. (1995). “Photon-measurement density functions. Part I: Analytical forms.” Applied Optics, 34(31), 7395–7409. [doi] — The formal definition of the sensitivity map discussed in Section 2, derived from the diffusion equation for several measurement types. Advanced reading.
  4. Fang, Q. & Boas, D.A. (2009). “Monte Carlo simulation of photon migration in 3D turbid media accelerated by graphics processing units.” Optics Express, 17(22), 20178–20190. [doi] — Introduces MCX, the GPU-accelerated Monte Carlo code widely used to compute sensitivity maps for fNIRS.
  5. Dehghani, H., Eames, M.E., Yalavarthy, P.K., Davis, S.C., Srinivasan, S., Carpenter, C.M., Pogue, B.W. & Paulsen, K.D. (2008). “Near infrared optical tomography using NIRFAST: Algorithm for numerical model and image reconstruction.” Communications in Numerical Methods in Engineering, 25(6), 711–732. [doi] — Describes NIRFAST, a finite-element package for solving the diffusion equation and reconstructing DOT images.
  6. Liebert, A., Wabnitz, H., Steinbrink, J., Obrig, H., Möller, M., Macdonald, R., Villringer, A. & Rinneberg, H. (2004). “Time-resolved multidistance near-infrared spectroscopy of the adult head: intracerebral and extracerebral absorption changes from moments of distribution of times of flight of photons.” Applied Optics, 43(15), 3037–3047. [doi] — Shows how photon arrival times separate intracerebral from extracerebral absorption changes in the adult head.
  7. Pifferi, A., Contini, D., Dalla Mora, A., Farina, A., Spinelli, L. & Torricelli, A. (2016). “New frontiers in time-domain diffuse optics, a review.” Journal of Biomedical Optics, 21(9), 091310. [doi] — Review of time-domain concepts such as time-gating, and of the technology making TD systems compact and wearable.
  8. Jacques, S.L. (2013). “Optical properties of biological tissues: a review.” Physics in Medicine and Biology, 58(11), R37–R61. [doi] — Reference values for tissue absorption and scattering, useful when setting up any of the models in Section 1.

Society for Functional Near-Infrared Spectroscopy.
Content is for educational purposes.