Serving the fNIRS community
The analyses of Lessons 5.1 to 5.3 all happen in channel space: every result is attached to a source-detector pair, and its location is described by the position of that pair on the scalp. This is simple and effective, but it has two limitations. A channel does not tell you where in the tissue beneath it a change occurred, and the same channel lies over slightly different brain tissue in different people. Image reconstruction addresses both by converting the measurements of many channels into an image of where the changes most likely took place inside the head.
In Lesson 2.4, we introduced diffuse optical tomography and what high-density arrays make possible. In this lesson, we look at how reconstruction actually works, which assumptions it rests on, and how it changes the analysis. We close with a question that many fNIRS users ask and that has no simple answer: is reconstruction worth doing when the probe is sparse, with channels that barely overlap?
Reconstruction starts from the opposite direction. Before asking where a measured change came from, we need to know how a change at any location in the head would affect each channel. This prediction is called the forward model, and building it requires three ingredients. The first is a head model: a three-dimensional description of the head divided into tissue types (scalp, skull, cerebrospinal fluid, gray matter, white matter), each with its own optical properties. It can come from the participant’s own MRI or, more often, from an atlas adjusted to the participant’s head size. The second is the position of every optode on that head, ideally digitized during the session (Lesson 4.2). The third is a simulation of how light travels through the head from each source to each detector, usually with Monte Carlo methods or numerical solutions of the diffusion equation (Lesson 2.5).
The result is a sensitivity matrix, which states, for every channel and every small volume of tissue (a voxel), how much a change in absorption in that voxel would change the optical density measured by that channel. Each row of the matrix is the banana-shaped sensitivity profile of one channel that we met in Lesson 2.5, now computed on a realistic head. For small changes, the relation between the image and the measurements is linear, and it can be written in one line.
💡 The Forward Model
$$\Delta \mathbf{y} = \mathbf{A}\,\Delta \mathbf{x}$$
\(\Delta \mathbf{y}\) contains the changes in optical density of all channels (tens to a few thousand values), \(\Delta \mathbf{x}\) contains the changes in absorption in every voxel of the head (tens of thousands of values), and \(\mathbf{A}\) is the sensitivity matrix. With one channel and a single homogeneous voxel, this reduces to the modified Beer-Lambert law (Lesson 2.5).
Reconstruction is the inverse: given \(\Delta \mathbf{y}\) and \(\mathbf{A}\), estimate \(\Delta \mathbf{x}\).
Inverting the forward model is difficult for two reasons. The problem is underdetermined: there are far more voxels than channels, so infinitely many images reproduce the measurements equally well. And it is ill-posed: because light diffuses, the sensitivity profiles of neighboring voxels are very similar, so tiny amounts of noise in the measurements can produce large, meaningless changes in the image. A direct inversion would be dominated by noise.
The solution is regularization: adding an assumption that selects one image among the many compatible with the data, typically the one that is smallest or smoothest while still fitting the measurements reasonably well. The strength of this assumption is set by a regularization parameter. Strong regularization gives stable but blurred images with smaller amplitudes; weak regularization gives sharper images that are more affected by noise. There is no single correct value, and the choice changes both the size and the apparent extent of a response.
Depth adds a further complication. Sensitivity falls steeply with depth, so a standard regularized solution tends to explain a change with superficial voxels, where a small change produces a large signal, rather than with deeper ones. Reconstructions therefore tend to place activations too close to the surface unless this bias is compensated, for example by adjusting the regularization so that deeper voxels are penalized less. Such compensation improves localization in depth but also amplifies noise there, which is another trade-off rather than a free improvement. The overall performance of a given array and reconstruction can be summarized by how a single point-like change is imaged: how wide its image is (resolution) and how far its peak is displaced from the true location (localization error).
How much reconstruction can recover depends above all on the measurements. Overlapping channels at several separations sample the same tissue from different angles and depths, and it is this redundancy that lets the inversion separate nearby locations and different depths. White and Culver (2010) compared a high-density array with two common sparse arrays, in simulations and in measurements of the visual cortex, and found that the high-density array gave substantially better resolution and smaller localization errors; it could map the detailed layout of the visual field, while the sparse arrays could only image the responses to individual block-design stimuli. With high-density arrays covering large parts of the head, diffuse optical tomography can produce maps that are directly comparable with fMRI (Eggebrecht et al., 2014).
With a sparse array, in contrast, each part of the cortex is seen by at most one or two channels at a single separation. The inversion has little information to work with, and the reconstructed image is essentially each channel’s sensitivity profile scaled by its measurement: smooth, depth-limited, and no more detailed than the channels themselves.
🔬 Explore It Yourself
Place a small absorption change in the tissue and reconstruct it with a sparse or a high-density array. Change the regularization strength and the noise, and try the depth compensation: without it, the image sits too close to the surface; with too much, it sinks too deep.
Every reconstructed image rests on assumptions that are easy to forget once it is displayed on a brain surface. The table summarizes the main ones.
| Assumption | When it fails |
|---|---|
| The head model represents the participant’s anatomy | With an atlas, differences in scalp and skull thickness, cerebrospinal fluid, and cortical folding shift the true sensitivity, especially in infants, older adults, and clinical populations with atypical anatomy |
| Optode positions are known | Without digitized positions, errors in placement become errors in the location of the image (Lesson 4.2) |
| The background optical properties are correct | The sensitivity matrix depends on assumed absorption and scattering, which vary between people and wavelengths (Lesson 4.3) |
| Changes are small, so the relation is linear | Usually reasonable for functional responses; less so for large changes, such as those in some clinical conditions |
| Superficial physiology has been handled | Reconstruction does not remove systemic signals. With multiple separations, the image can assign some of them to superficial layers, but the regression steps of Lesson 5.3 remain necessary |
Underlying all of these is a more general limit: reconstruction cannot create information that the measurements do not contain. It redistributes the information of the channels into a spatial representation, guided by the head model and the regularization. When the measurements are rich, this representation is genuinely more informative than the channels. When they are not, the image mostly reflects the assumptions.
Because common reconstruction methods are linear, the order question of Lesson 5.1 applies again. One option is to reconstruct the optical density time series of each wavelength, convert each voxel to HbO₂ and HbR, and apply the GLM voxel by voxel. The other is to apply the GLM in channel space and reconstruct only the estimated responses. With the same model, the two give equivalent results, and the second is much faster; the first is needed when the analysis itself works on time series, as in the connectivity analyses of Lesson 5.5.
Image space changes the group analysis in two ways. On the positive side, all participants are expressed in the same anatomical space, so a voxel or an atlas region means the same thing in everyone, even when probes were placed slightly differently or heads differ in size, and results can be compared directly with fMRI or with other studies. On the other side, an image contains thousands of voxels, many more tests than channels, but neighboring voxels are strongly correlated because they were reconstructed from the same few measurements. The correction for multiple comparisons (Lesson 5.3) must therefore take this correlation into account, for example with methods developed for fMRI images, or the analysis must be restricted to a few regions defined in advance from an atlas.
⚠ A Common Mistake to Avoid
Not every colorful map of fNIRS data is a reconstructed image. Topographic maps are often produced by interpolating channel values between their positions on the scalp. They look smooth and detailed, but the gradients between channels are a property of the interpolation, not of the brain, and they contain no more spatial information than the channels.
Even a true reconstruction from a sparse array can look more precise than it is. When you read or present a map, ask how many channels contributed to each part of it, how the positions were registered, and which head model and regularization were used.
For high-density arrays, the answer is clearly yes: reconstruction is how their overlapping measurements become better resolution and depth discrimination. For the sparse arrays used in most fNIRS studies, the field has not reached a consensus, and the answer depends on what you want from the images.
What reconstruction does not give a sparse array is resolution or depth discrimination beyond what its channels contain (Section 3). What it can give is a principled way of moving the data into a common anatomical space: each channel’s contribution is weighted by its actual sensitivity to each part of the brain, given the participant’s head and the measured optode positions. Several groups have developed and validated pipelines for doing this with conventional arrays. Wijeakumar et al. (2017) compared image-based fNIRS with fMRI during a working memory task and found corresponding effects across fronto-parieto-temporal regions, and Forbes et al. (2021) showed good correspondence between channel-based and image-based results in a longitudinal study of children.
Whether this matters in a given study depends largely on how much the placement of the probe relative to the brain varies. Collins-Jones et al. (2021) addressed this question in a longitudinal study of infants between 5 and 12 months of age, a period of rapid head growth. Using image reconstruction, they found that variability in the position of the array was the main factor that changed the inferences drawn from the data. At the individual level, this variability mattered; at the group level, with 40 to 53 infants per age, the conclusions of a conventional channel-space analysis were robust to it. In other words, channel-space analysis can be adequate for group conclusions when placement is consistent and samples are large, while reconstruction becomes more valuable for individual-level inferences, for populations whose heads differ or change, and for comparing results across probes, studies, and imaging modalities.
💭 Pause and Think
You are planning two studies with the same sparse prefrontal probe. The first compares a large group of young adults between two conditions in a single session. The second follows a small number of patients after stroke over six months, to track changes in each patient’s response. In which study would image reconstruction add more, and what would you need to collect during the sessions to make it worthwhile?
Think about individual versus group inferences, how consistently the probe can be placed across sessions, how a lesion changes the anatomy assumed by an atlas, and what optode digitization and an individual MRI would provide.
Image reconstruction turns channel measurements into estimates of where changes occurred inside the head, using a physical model of light propagation and an explicit assumption to resolve the ambiguity of the inversion. With dense, overlapping measurements, it delivers resolution, depth discrimination, and maps that can be compared with other imaging methods. With any array, it places the data in a common anatomical space that accounts for each channel’s sensitivity and for differences in probe placement.
It cannot add information that the measurements lack, remove physiology that was not handled, or make the image independent of the head model and the regularization that produced it. Reporting these choices is therefore part of reporting the result, as we will see in Lesson 5.6. In the next lesson, we move from where changes occur to how signals relate to each other, within a brain and between people.
📌 Key Takeaways
📚 Further Reading & Key References
Society for Functional Near-Infrared Spectroscopy.
Content is for educational purposes.