Serving the fNIRS community
Nothing in the physics of Unit 2 is specific to the brain. Near-infrared light enters any tissue, scatters, is absorbed by hemoglobin, and returns to the surface carrying information about the oxygenation of the tissue it crossed. In Lesson 1.1, we saw that NIRS was applied to muscle from its early days, and in Lesson 1.3 we used the working muscle of an elite rower to show that oxygenation reflects the balance between oxygen delivery and consumption. Muscle oximetry is today one of the most widespread uses of NIRS, in exercise physiology, sports science, rehabilitation, and the study of diseases that affect how muscles receive and use oxygen.
This lesson asks the question of this unit for muscle: why NIRS, and not another tool? We describe what NIRS measures in muscle and how it differs from the brain, the occlusion methods that turn changes in oxygenation into blood flow and oxygen consumption, how NIRS is used during exercise in muscle and brain together, and the limits that are specific to muscle, above all the layer of fat that lies between the probe and the tissue of interest.
In some ways, muscle is an easier target than the brain. There is no skull, the tissue of interest can lie just a few millimeters under the skin, and the changes in oxygenation during exercise are large, often much larger than those of a cortical response. Hampson and Piantadosi (1988) showed how directly NIRS could follow muscle oxygenation: when they stopped blood flow to the forearm with a tourniquet, the oxygenated hemoglobin and myoglobin of the muscle fell steadily over a few minutes as the muscle consumed its oxygen stores, and when the tourniquet was released, a rush of oxygenated blood restored them. A few years later, Chance et al. (1992) used a simple muscle spectrophotometer on the quadriceps of elite rowers and measured how long the muscle took to reoxygenate after intense exercise, a recovery time that ranged from 10 to 80 seconds between athletes and that they interpreted as the time needed to repay the oxygen deficit accumulated during the effort.
Other techniques can measure aspects of muscle oxygen delivery and use, and each answers a different question. Phosphorus magnetic resonance spectroscopy (31P-MRS) measures the energy metabolism of the muscle directly and is the reference method for its oxidative capacity, but it requires a scanner and allows only small movements inside it. Doppler ultrasound measures blood flow in a large artery, but not how much oxygen the tissue extracts from it. Blood sampling from a vein draining the limb measures oxygen extraction, but it is invasive and mixes blood from many muscles. Breath-by-breath gas exchange measures the oxygen consumption of the whole body, not of a single muscle. NIRS is the only one of these that measures the oxygenation of a specific muscle, noninvasively, continuously, and during real exercise, on a cycle ergometer, on a rowing machine, or on the field. That is why it is the tool of choice for many questions in exercise physiology, and why its limits deserve the same scrutiny as in the brain.
The quantities are the same as in the brain (ΔHbO₂, ΔHbR, HbT, and, with the right instrument, StO₂), and so is their interpretation as a balance between delivery and consumption (Lesson 1.3). As in the brain, the signal comes mostly from the small vessels, the arterioles, capillaries, and venules, because large vessels contain so much blood that they absorb nearly all the light that enters them. Muscle adds one important complication: myoglobin, the protein that stores oxygen inside muscle cells. Myoglobin is an oxygen-binding heme protein like hemoglobin, and in the near infrared the spectra of their oxygenated and deoxygenated forms are almost identical, so NIRS cannot separate them. Muscle NIRS signals are therefore best described as changes in hemoglobin plus myoglobin, and careful papers label them that way. How much each contributes is still debated: Davis and Barstow (2013), estimating from published data on muscle composition, concluded that myoglobin could account for more than half of the absorbing heme in resting muscle and most of the change during exercise. Whatever the exact proportion, the practical consequence is that a muscle NIRS signal reflects oxygen inside the cells as well as in the blood, which is part of what makes it useful and part of what makes it hard to interpret.
Muscle also behaves differently from the brain during activity. When a muscle contracts strongly, the pressure inside it rises and squeezes blood out of its vessels, so blood volume and flow can fall during the contraction itself and rise sharply when it relaxes. A fall in HbO₂ during a contraction may therefore reflect compression as well as consumption. And because the oxygen demand of a working muscle can rise much more than that of the brain, the classic pattern of brain activation, in which flow overshoots consumption and HbO₂ rises, often reverses in muscle: during intense exercise, the muscle deoxygenates, as we saw in Lesson 1.3.
The oxygenation of a tissue depends on both delivery and consumption, so, by itself, it cannot tell you either one (Lesson 1.3). In the brain, separating them requires additional measurements, such as blood flow from diffuse correlation spectroscopy (Lesson 4.4). In a limb, there is a simpler option: a pressure cuff around the arm or thigh can stop the flow of blood in a controlled way, and the change in the NIRS signal during the occlusion then isolates one side of the balance. De Blasi et al. (1994) inflated a cuff to 50 mmHg, a pressure that blocks the veins but not the arteries, and showed that forearm blood flow measured from the rise in HbT agreed closely with a standard method (r = 0.94); they also obtained oxygen consumption from the same maneuver. Hamaoka et al. (1996) used a full arterial occlusion immediately after exercise and showed that the rate at which hemoglobin and myoglobin lost their oxygen correlated closely with the metabolic measures of 31P-MRS. Figure 1 shows what the two kinds of occlusion look like.
💡 Two Occlusions, Two Quantities
Venous occlusion (cuff pressure below arterial pressure, typically around 50 mmHg). Blood keeps flowing in but cannot leave, so blood accumulates in the tissue at a rate set by the arterial inflow:
$$\text{blood flow} \;\propto\; \frac{d[\text{HbT}]}{dt}$$
Arterial occlusion (cuff pressure above systolic pressure). Nothing flows in or out, so HbT stays constant, and the only thing that changes the signal is the oxygen the tissue consumes:
$$\text{oxygen consumption} \;\propto\; -\frac{d[\text{HbO}_2]}{dt} \;=\; \frac{d[\text{HbR}]}{dt}$$
Here [HbO₂] and [HbR] include myoglobin. Converting the slopes into absolute units requires the hemoglobin concentration of the blood and, for CW instruments, the path length, so many studies report the slopes, or ratios between conditions, rather than absolute values.
Figure 1. What the two occlusions look like (simulated, illustrative values). (a) During a venous occlusion, blood accumulates and HbT rises; its initial slope is proportional to blood flow. (b) During an arterial occlusion, HbT stays constant, and the steady fall of HbO₂ (and rise of HbR) is proportional to oxygen consumption. Releasing the cuff produces a brief overshoot of flow, called reactive hyperemia.
The same idea, repeated, measures how quickly a muscle’s mitochondria can respond to demand. After a brief bout of exercise, a series of short arterial occlusions, each lasting a few seconds, gives a measurement of oxygen consumption at many points during recovery. Consumption returns to its resting value along an approximately exponential curve, and the time constant of that curve reflects the muscle’s oxidative capacity. Ryan et al. (2013) compared this NIRS measurement with the recovery of phosphocreatine measured by 31P-MRS in the same participants and found the same average time constant (31.5 seconds) and strong correlations between the two methods (r = 0.88 and 0.95 for two NIRS channels). A measurement that once required a scanner can therefore be made with a portable device and a cuff, in the clinic or at the bedside, which has opened studies of oxidative capacity in aging and in diseases that affect muscle.
During exercise of increasing intensity, the oxygenation of the working muscle typically falls as consumption outpaces delivery, and the shape of that fall, with its plateaus and changes of slope, is used to study how delivery and consumption are matched, how they change with training, and where they fail in disease. Wearable muscle oximeters have taken these measurements from the laboratory to training sessions and competitions, and NIRS has been used to study muscle oxygenation in chronic heart failure, peripheral vascular disease, chronic obstructive pulmonary disease, muscle diseases, and other conditions in which delivery or use of oxygen is impaired (Hamaoka et al., 2007).
Because the same instrument can be placed on the head and on a muscle at the same time, NIRS also allows the brain and the working muscle to be studied together, which is attractive for questions about fatigue and about what limits performance. Rupp and Perrey (2008) measured the vastus lateralis and the prefrontal cortex of trained cyclists during an incremental test to exhaustion. Muscle oxygenation fell throughout the test, while prefrontal oxygenation rose during the first minutes and then fell markedly from the second ventilatory threshold until exhaustion, a pattern the authors related to the brain’s role in limiting effort. Part of that fall is expected from physiology alone: at high intensities, people breathe more than they need to, CO₂ falls, and the brain’s vessels constrict (Lesson 3.5).
Exercise is also where the scalp problem of Lesson 3.5 is at its worst. As the body heats up, blood flow to the skin increases to dissipate heat, and the forehead is no exception. Miyazawa et al. (2013) measured forehead skin blood flow, NIRS over the forehead, and blood flow velocity in the middle cerebral artery during moderate cycling, and then cooled the face with a cold mist. Cooling reduced skin blood flow and the NIRS HbO₂ signal together, while cerebral blood flow velocity did not change, and in each participant the changes in HbO₂ correlated strongly with those in skin blood flow (r = 0.71 to 0.99). Studies of the brain during exercise therefore need short-separation channels, or the depth-resolved measurements of Lesson 4.3, even more than studies at rest.
💭 Pause and Think
A study uses arterial occlusions to compare forearm muscle oxygen consumption between men and women, and finds it is markedly lower in women. The authors suggest a sex difference in muscle metabolism. What would you check before accepting this interpretation?
Think about what lies between the probe and the muscle, whether that layer differs on average between the two groups, how it would affect the fraction of detected light that reached the muscle, and what you would need to measure to separate the two explanations. Then read Section 5.
The most important limit is the muscle’s equivalent of the scalp: the layer of skin and subcutaneous fat above it. Fat absorbs little light and has little blood, so the part of the light’s path that runs through it contributes almost nothing to the signal, and the thicker the layer, the smaller the fraction of the detected light that has reached the muscle. The consequence is not a small correction. van Beekvelt et al. (2001) measured forearm muscle oxygen consumption in 78 healthy adults with skinfold thicknesses between 1.4 and 8.9 mm, and found that the measured consumption decreased strongly as fat thickness increased (r = −0.70): the 10 leanest participants appeared to consume twice as much oxygen as the 10 with the most fat. The difference they found between women and men was due to the difference in fat thickness. Comparisons between people or groups therefore require the fat layer to be measured, usually with skinfold calipers or ultrasound, and either matched between groups or corrected for, and the source-detector separation must be long enough for the light to reach the muscle through the thickest layer in the sample.
🔬 Explore It Yourself
Change the thickness of the skin and fat layer and the source-detector separation, and watch how much of the detected light still reaches the muscle, and how much an occlusion measurement would underestimate oxygen consumption. Compare a lean forearm with a thick fat layer, and see how far a longer separation helps.
Other limits will sound familiar from the brain. A CW instrument measures changes, and their size depends on a path length that differs between muscles and between people (Lesson 2.2). Absolute values of StO₂ require spatially resolved, frequency-domain, or time-domain measurements (Lesson 4.3), and different instruments and algorithms can report different values for the same tissue, so values from different devices should not be compared directly. Skin blood flow rises during prolonged exercise and in the heat, adding a superficial signal, and skin pigmentation reduces the light that reaches the muscle (Lesson 4.2). The probe samples a few cubic centimeters of superficial muscle, which may not represent the whole muscle, let alone the whole limb, and its placement, the pressure with which it is held, and its movement with the contracting muscle all affect the signal. None of these limits prevent good studies, but each must be designed around, exactly as in the brain.
⚠ A Common Mistake to Avoid
It is tempting to treat the StO₂ value displayed by a muscle oximeter as a property of the muscle that can be compared freely between people, sessions, and devices. The value depends on the instrument, its algorithm, the thickness of the fat layer, skin pigmentation, and the placement of the probe, as well as on the muscle itself.
Changes within a session, measured at the same site with the same device, are far more robust than absolute values compared between people. When you compare groups, measure the fat layer, report the instrument and its settings, and prefer measures that are less sensitive to these factors, such as slopes during occlusions or recovery time constants.
🎍 MUST-READ PAPER
Barstow, T.J. (2019). “Understanding near infrared spectroscopy and its application to skeletal muscle research.” Journal of Applied Physiology, 126(5), 1360–1376.
A tutorial on muscle NIRS written for reproducibility: the main types of instruments and what each can measure, the confounding factors (fat thickness among them), and practical recommendations for collecting, analyzing, and interpreting muscle data. The muscle counterpart of the best-practice papers of Lesson 5.6.
📝 NOTE: Muscle in Your Brain Data
Muscle can also appear where you do not want it. Probes over the temporal cortex lie on top of the temporalis, the large chewing muscle on the side of the head, and probes over the occipital cortex may cover neck muscles. Clenching the jaw, chewing, talking, or tensing the neck changes the oxygenation and blood volume of these muscles, and the change reaches the detectors along with the brain signal. This is one more reason to ask participants to avoid clenching (Lesson 4.2), to record or video the participant, and to be cautious with tasks that require speaking or chewing.
Muscle NIRS is a mature application in its own right, but it is also a useful mirror for brain fNIRS. The occlusion methods show what becomes possible when delivery or consumption can be controlled, which is exactly what the brain does not allow and why multimodal measurements such as NIRS combined with DCS matter there (Lesson 4.4). The fat layer is the clearest demonstration of what the scalp does to brain signals: a superficial layer that differs between people can create group differences that have nothing to do with the tissue of interest. And the community’s response, which is to measure the confounding layer, report the instrument, and prefer quantities that are robust to it, is the same one we have recommended throughout Units 4 and 5.
📌 Key Takeaways
📚 Further Reading & Key References
Society for Functional Near-Infrared Spectroscopy.
Content is for educational purposes.